FixPt Multiport Switch
Switch output between different inputs based on the value of the first input.
Description
The FixPt Multiport Switch block is a masked S-function that passes through the data input specified by the first (top) input. The first input is called the control input, while the rest of the inputs are called data inputs.
If the control input is an integer value, then the specified data input is passed through to the output. For example, if the control input is 1, then the first data input is passed through to the output. If the control input is not an integer value, the block truncates the value to an integer by rounding to floor. If the truncated control input is less than 1 or greater than the number of input ports, an out-of-bounds error is returned.
The block inputs can be scalar or vector. You specify the number of data inputs with the Number of input ports parameter. The block output is determined by these rules:
If you specify only one data input and that input is a vector, the block behaves as an "index selector," and not as a multi-port switch. The block output is the vector element that corresponds to the value of the control input.
If you specify more than one data input, the block behaves like a multi-port switch. The block output is the data input that corresponds to the value of the control input. If at least one of the data inputs is a vector, the block output is a vector. Any scalar inputs are expanded to vectors.
If the inputs are scalar, the output is a scalar.
For a detailed description of all other block parameters, refer to Block Parameters.
The output data type is determined by the data input with the largest positive range.
Parameters and Dialog Box
Number of input ports - The number of data inputs to the block.
Output data type and scaling - Inherit the output data type and scaling from the driving block or by back propagation.
Round toward - Rounding mode for the fixed-point output. This parameter does not apply to an integer control input.
Saturate to max or min when overflows occur - If checked, fixed-point overflows saturate. Otherwise, they wrap. This parameter does not apply to an integer control input.
Log minimums and maximums - If checked, minimum and maximum simulation values are logged to the workspace.
Characteristics
Input Ports | Any data type supported by the blockset |
Output Port | Any data type supported by the blockset |
Direct Feedthrough | Yes |
Sample Time | Inherited |
Scalar Expansion | Yes |
States | 0 |